Skip to search boxSkip to navigationSkip to main content

Continuous exercise induces airway epithelium damage while a matched-intensity and volume intermittent exercise does not

  • Adrien Combes
    ,
  • ,
  • Xavier Dumont
    ,
  • Rosie Twomey
    ,
  • Alfred Bernard
    ,
  • Frederic Daussin
  • Universite de Lille 2
    ,
  • Universite des Sciences et Technologies de Lille
    ,
  • ,
  • Université catholique de Louvain
    ,
  • University of Calgary
Research output:
Contribution to journal
Article
Research
Peer-review

Open access

About the research

<p>Background: While continuous exercise (CE) induces greater ventilation (V <sub>E</sub>) when compared to intermittent exercise (IE), little is known of the consequences on airway damage. Our aim was to investigate markers of epithelial cell damage - i.e. serum levels of CC16 and of the CC16/SP-D ratio - during and following a bout of CE and IE of matched work. Methods: Sixteen healthy young adults performed a 30-min continuous (CE) and a 60-min intermittent exercise (IE; 1-min work: 1-min rest) on separate occasions in a random order. Intensity was set at 70% of their maximum work rate (WR <sub>max</sub>). Heart rate (HR) and V V <sub>E</sub> were measured throughout both tests. Blood samples were taken at rest, after the 10th min of the warm-up, at the end of both exercises, half way through IE (matched time but 50% work done for IE) as well as 30- and 60-min post-exercise. Lactate and CC16 and SP-D were determined. Results: Mean V V <sub>E</sub> was higher for CE compared to IE (85 ± 17 l.min <sup>- 1</sup> vs 50 ± 8 l.min <sup>- 1</sup>, respectively; P < 0.001). Serum-based markers of epithelial cell damage remained unchanged during IE. Interaction of test × time was observed for SP-D (P = 0.02), CC16 (μg.l <sup>- 1</sup>) (P = 0.006) and CC16/SP-D ratio (P = 0.03). Maximum delta CC16/SP-D was significantly correlated with mean V V <sub>E</sub> sustained (r = 0.83, P < 0.001) during CE but not during IE. Conclusion: The 30-min CE performed at 70% WR <sub>max</sub> induced mild airway damage, while a time- or work-matched IE did not. The extent of the damage during CE was associated with the higher ventilation rate. </p>

Research output information

Output type

Research output:
Contribution to journal
Article
Research
Peer-review

Original language

English

Article number

12

Journal (Volume, Issue Number)

Respiratory Research (Volume 20, Issue 1)

Publication milestones

  • Accepted/In press - 06/01/2019
  • Published - 17/01/2019

Publication status

Published - 17/01/2019

ISSN

1465-9921